The PER Meter is a new generation of precision optical detection instruments. It can provide 1~8 channels extinction ratio measurements of optical fibers, polarization-maintaining devices, polarization angle of light sources, polarization-maintaining fibers and optical components, power consumption, and advanced axis angles with remarkable precision and speed. It features large PER measurement range, high- precision stability, powerful and easy to use software, and multi-channel tests of temperatures and insertion loss.
@font-face {font-family:宋体; panose-1:2 1 6 0 3 1 1 1 1 1; mso-font-alt:SimSun; mso-font-charset:134; mso-generic-font-family:auto; mso-font-pitch:variable; mso-font-signature:515 680460288 22 0 262145 0;}@font-face {font-family:"Cambria Math"; panose-1:2 4 5 3 5 4 6 3 2 4; mso-font-charset:0; mso-generic-font-family:roman; mso-font-pitch:variable; mso-font-signature:-536870145 1107305727 0 0 415 0;}@font-face {font-family:DengXian; panose-1:2 1 6 0 3 1 1 1 1 1; mso-font-alt:等线; mso-font-charset:134; mso-generic-font-family:auto; mso-font-pitch:variable; mso-font-signature:-1610612033 953122042 22 0 262159 0;}@font-face {font-family:Georgia; panose-1:2 4 5 2 5 4 5 2 3 3; mso-font-charset:0; mso-generic-font-family:roman; mso-font-pitch:variable; mso-font-signature:647 0 0 0 159 0;}@font-face {font-family:"@宋体"; panose-1:2 1 6 0 3 1 1 1 1 1; mso-font-charset:134; mso-generic-font-family:auto; mso-font-pitch:variable; mso-font-signature:515 680460288 22 0 262145 0;}@font-face {font-family:"@等线"; panose-1:2 1 6 0 3 1 1 1 1 1; mso-font-alt:"@DengXian"; mso-font-charset:134; mso-generic-font-family:auto; mso-font-pitch:variable; mso-font-signature:-1610612033 953122042 22 0 262159 0;}p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-unhide:no; mso-style-qformat:yes; mso-style-parent:""; margin:0; text-align:justify; text-justify:inter-ideograph; mso-pagination:none; font-size:16px; font-family:DengXian; mso-ascii-font-family:DengXian; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:DengXian; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:DengXian; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi; mso-font-kerning:1px;}pre {mso-style-priority:99; mso-style-link:"HTML 预设格式 字符"; margin:0; margin-bottom:0; mso-pagination:widow-orphan; font-size:16px; font-family:宋体; mso-bidi-font-family:宋体;}span.HTML {mso-style-name:"HTML 预设格式 字符"; mso-style-priority:99; mso-style-unhide:no; mso-style-locked:yes; mso-style-link:"HTML 预设格式"; font-family:宋体; mso-ascii-font-family:宋体; mso-fareast-font-family:宋体; mso-hansi-font-family:宋体; mso-bidi-font-family:宋体; mso-font-kerning:0;}.MsoChpDefault {mso-style-type:export-only; mso-default-props:yes; font-size:16px; mso-ansi-font-size:16px; font-family:DengXian; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi; mso-ligatures:none;}div.WordSection1 {page:WordSection1;}




Features
Multi-channel expansion via stackable modules and programmable system
High accurate and stable measurements of multi-channel temperatures and insertion loss
Wide PER measurement range
3 wavelength ranges: 400nm~700nm,600nm~1200nm and 1200nm~1700nm
Applications
Monitoring of polarization-maintaining fiber splicing
Alignment of polarization axis of optical devices
Alignment of polarization-maintaining fibers with laser light sources
Measurement of the extinction ratio of polarization-maintaining fibers
Measurement of PM couplers (PMC) and polarization beam splitters (PBS)
Measurement of PM fiber axis angle
Measurement of Y-branch optical fiber gyroscope
Specifications
Model | PER4100-P-L | PER4100-P-M | PER4100-P-H |
Wavelength Range | 400 to 700nm | 600 to 1200nm | 1200 to 1700nm |
Maximum Input Power | +10dBm | ||
Input Power Range | -30 to +10dBm | -40 to +10dBm | -40 to +10dBm |
Maximum PER | 30dB | 40dB | 40dB |
PER Dynamic Range | 400 to 500nm: 20dB | -30 to +10dBm: 40dB | -30 to 10dBm: 50dB |
500 to 700nm: 30dB | -40 to -30dBm: 30dB | -40 to -30dBm: 40dB | |
PER Resolution | <10dB: 0.001dB; ≥10dB: 0.01dB | ||
PER Accuracy | PER≤2dB: ≤±0.1dB; PER<30dB: <±0.3dB; PER≥30dB:<±1.0dB | ||
Polarization Angle Resolution | 0.11° | ||
Polarization Angle Accuracy | < ±0.45° | ||
Measurement Speed | 0.25s | ||
Optical Connector Type | FC/PC (interchangeable SC/LC) | ||
Communication Interface | RS232 | ||
Operation System | Win7 (32/64-bit), Win10 (32/64-bit) | ||
Monitor | 21” monitor with minimum resolution of 1600×900(recommended) | ||
Warm-up Time | 15min | ||
Power Supply | AC 220V, 50Hz | ||
Operating Temperature | +10 to +40℃ | ||
Storage Temperature | -15 to +70℃ | ||
Dimension | 3U×450×440 mm | ||