PRI3305 handheld insertion loss and return loss tester is a portable version tester of BRI3304 series of benchtop return loss and insertion loss testers. The performance of the instrument is stable and reliable.
With built-in stable light source, high-precision power meter, return loss test, insertion loss tester, visual fault locator and fiber optic microscope, it is widely used in insertion loss and return loss test of optical fiber and cable, optical passive device, and optical fiber communication systems. It is a basic test instrument widely used by device manufacturers, scientific research institutions and operators for production testing, research and development and engineering construction and maintenance.
Features
l Multiple measurement mode
l Automatic measurement and display of multi wavelengths
l 5.6” LCD touch screen
l Configurable threshold value
l Warning indication
l Optional fiber optic microscope function
Application
l Data center equipment room
l Test of optical cables and passive components
l Maintenance of digital data networks
l Teaching and researching of fiber optic communication
Specifications
Model | PRI3305 |
Return Loss | |
Wavelength (nm) | 1310/1550(±10) or 850/1300nm |
output power (dBm) | ≥-3 |
Spectral width (FWHM) | ≤5nm |
Connector type | FC/APC |
Frequency(HZ) | CW,270,1K,2K |
Power stability (dB) 2 | ≤±0.05(15 min @ 25℃) |
Testing range (dB) | 0~75 |
Display resolution (dB) | 0.1 |
Test accuracy(dB)3 | ±0.5 |
Insertion Loss | |
Detector type | InGaAs |
wavelength coverage (dBm) | 800~1700 |
Calibration wavelength(nm) | 850,1300,1270,1310,1490,1550,1577,1625 |
Measuring range (dBm) | +10~-70 |
Linearity (dB)4 | ±0.15(+10~-60)dBm |
Optical interface | FC, SC, ST, LC, 2.5mm universal, 1.25mm universal |
Power unit | dBm, dB, xW |
Resolution ratio(dB) | 0.01 |
Record storage | Yes |
VFL | |
Wavelength (nm) | 650 |
Output power(mW) | 10 |
Other | |
Display screen | 5.6-inch TFT color screen |
Power supply mode | 7.4V 52000mAh Lithium battery / power adapter 12-19V 2A |
Automatic shutdown time | Custom optional |
Low battery warning | icon flash |
Communication interface | Ethernet port、Micro USB |
Working temperature (℃) | -10~+60 |
Storage temperature (℃) | -25~+70 |
Size (mm) | 260×155×73 |
Weight(g) | 1200 |
Note:
1. The above technical indicators are tested at T=23±2℃.
2. Need to turn on and preheat for 15 minutes before testing.
3. The test accuracy is compared with the standard table in the range of 0 ~ 65dB at 25℃ room temperature.