SA-2200 Spectrum
Analyzer is the first Android hand-held spectrum analyzer. It features high
testing sensitivity, light weight, compact size and portable design. Android
operating system and high-resolution touch screen allow testing and measurement
can be performed user-friendly.
With excellent performance, it meets the
testing and measurement requirements of the majority of RF signals.
Features
1. Frequency range: 10MHz to 6.0GHz
2. DANL: -166 dBm@1GHz (Sensitivity set to High, normalized to 1Hz)
3. RBW: 10Hz to 5MHz
4. Multi-screen: maximum 4 windows
5. Android operating system: touch screen operation, multi-touch, easy-to-use.
6. Compact size (200mm×96mm×67mm) and light weight (1.25kg, including the battery)
7. 6 hours full operating time battery
8. Provide
effective measurement guarantee during the building and maintenance of the transmission system
Applications
1. Set-up and maintenance of transmission system
It can be used
to establish and maintain transmission system which has the following
measurement functions: Signal spectrum quality testing, Mainstream
communication system signal testing, Applicable to the transmission test and
air interface test.
1) General spectrum test
2) Occupied bandwidth (OBW)
3) Channel power measurement
4) Adjacent channel leakage power ratio
5) Spectrum measurement of main communication signal
6) Portable and suitable for long-time
field test
2. Interference search
Compact design
allows users to place and use it anywhere at anytime. The long standby time
generally meets one-day field operation needs.
1) Precise weak signal measurement
2) Connect the omni-directional and directional antenna to check interference
3) Suitable and portable for long-time
testing
3. General test in laboratory, factory, school, etc.
General
spectrum analysis, it has the broadband test function, including frequency
test, power test, spurious test, etc.
1) Common test status auto-saving
2) Easy set-up
4. Software customization
We provide software
customizing services. Variety of application and software can be preinstalled
or build in SA-2200 as users demanded. It supports various customized software.
We carry out development and maintenance of customized applications to further
upgrade it based on user’s needs.
1) GNSS interference Analysis Application
Specifications
Model | SA2200 |
Measurement | ACPR,CH Power, OBW, Phase Noise, and N |
Trace | 3 Traces: A, B and C Trace operation: Clear/Write, Max hold, Min hold, Average, View, Hide |
Sweep | Continuous, single |
Trigger | Free Video (zero span) |
Marker | 8 maximum, support 1 reference with 7 Delta Markers Peak Search, Marker Delta, Marker+, Marker- |
Span | 0Hz, 100Hz to 6.0GHz Frequency Slip, Span Zoom (1-2-5-10 series, 4GHz, 6GHz) |
Scale | Log/Lin; Log: 0.1 to 1, 0.1 step; Lin: 1 to 10, 1 step |
Unit | dBm, dBuV, dBV, W, mW, uW, pW, V, mV, uV |
Sensitivity | Low, Medium and High |
Detector | Positive, Negative, Sample, Average, RMS |
Reference Level Offset | -50dB to 50dB |
Multi-screen | 4 maximum |
Frequency | |
Frequency Range | 10MHz to 6.0GHz |
Frequency Reference | Aging Rate: ±1ppm |
Frequency Readout Accuracy | ±( (Readout Frequency + 1GHz) x Frequency Reference + Frequency Span Accuracy x Span) |
Frequency Span Accuracy | ±1% |
Sweep Time | 1.2ms to 1600s; 3.99ms to 1600s, zero span |
Resolution Bandwidth | |
RBW Range | 10Hz to 5MHz (1-2-3-5-10 Series) |
RBW Accuracy | RBW≥1MHz, ±10%; RBW<1MHz, ±2% |
Amplitude | |
Measuring Range | Display Average Noise Level to +20dBm |
Input Attenuator Range | 0 to 30dB, 1dB Step |
Maximum Safe Input Level | Sensitivity (Low): +30dBm Sensitivity (Medium): 0dBm Sensitivity (High): -20dBm |
Reference Level Range | -140dBm to +20dBm; -190dBm to +70dBm (Reference level offset: ON) |
Amplitude Accuracy | ATT set to 0 dB, input signal: -5 to -30dBm; detector
set to Positive, |
RBW Switching Uncertainty | ±0.3dB |
Input Attenuator Uncertainty | ±0.6dB |
Accuracy of Reference Level | Reference level ≥-60dBm, ±0.8dB |
Display Average Noise Level (DANL) @1GHz | Input Terminated, Detector set to Positive, Trace
Average set to 1000, Sensitivity Low: -129dBm/Hz (typically -132dBm/Hz) Sensitivity Medium: -149dBm/Hz (typically -152dBm/Hz) Sensitivity High: -166dBm/Hz (typically -168dBm/Hz) |
Residual Response | -75dBm |
Input-related Response | 10MHz to 1.1GH <70dBc; 1.85GHz to 2.9GHz, 2.97GHz to 3.11GHz, 3.7GHz to 5.6GHz <-50dBc 5.6GHz to 5.8GHz <-45dBc 3.11GHz to 3.7GHz, 5.8GHz to 6.0GHz <-39dBc |
Second Harmonic Distortion | 1.6GHz -70dBc |
Third-order Intercept (TOI) | -10dBm tones, 1MHz apart, Sensitivity set to low, Ref set to -10dBm+15dBm |
P1dB | +5dBm (nominal) |
Phase Noise @1GHz | -95dBc/Hz, @10kHz (typically -97dBc/Hz) -115dBc/Hz, @1MHz (typically -116dBc/Hz) |
General Information | |
System settings | Reset, Save, Recall, Screen Copy, Print, Language, Service, About |
Connectors | RF input: N-type, female, 50Ω USB: USB type C Power interface: Slim Tip, DC20V/4.5A |
Display | 5.5-inch, 720p |
Operating System | Android |
Battery | Type: Lithium-ion Operating time: 6hours Charging time: 2.5hours Charging temperature: 0°C to +35°C, Must be in power of state |
Operating Environment | Operating temperature: 0°C to 50°C Storage temperature: -20°C to 70°C |
Dimension | 200mm*99mm*67mm (7.8 in*3.9 in* 2.6in) |
Weight | 1.25kg (2.8lb) |