VT4302 Vector Network Analyzer is a 100kHz-8.5GHz high performance Vector Network Analyzer. It is the biggest characteristic can provide 2 or 4 Port Test Mode, thereby greatly improving the device of measuring speed and efficiency. Mainly used in wireless communications, radio and television, education, scientific research, automotive electronics, semiconductor and medical device fields.
The amplifier, coaxial cables,splitters,combiners,antenna,couplers,filters,isolator,branch distributor, crystal, surface acoustic devices such as RF amplitude-frequency characteristics, reflection properties, phase characteristics, delay characteristic in all aspects of measurement.
7) Special
calibration
------Max 4 port SOLT calibration
------Enhanced Response Calibration: it can eliminate directivity, crosstalk,
source matching,
reflection tracing, transmission tracing error
and improve test precision.
-----Port Extension: under some situation, calibration can not be done on the
test interface.
With port extension function, it can compensate phase shift/delay between the test port and under-test components,
and improve the efficiency.
-----TRL Calibration: it provide prevision test for non-coaxial components.
-----OPM Calibration: together with optical power meter, it can calibrate the
power output level of optical power meter.
------Receiver Calibration: it can calibrate the gain of single receiver under
absolute test mode.
8) Multi-External Ports: USB/LAN/RS232,keyboard PS/2, Mouse PS/2,external VGA
port, GPIB port(optional)
9) Easy to compose of auto test system
------Open Windows7 operating system supports the VBA programming via
macroinstruction.
6 USB ports, Standard LAN port and GPIB port (optional).
------GPIB and LAN ports are convenient to be composed of automatic test
system.
------LAN port is easy to access the LAN and wireless network card, and realize
the remote-control.
10) Multi-Windows/Multi-Channel/Multi-Traces can be displayed at one time .
Model |
VA4302 |
Frequency Range (Hz) |
100k~8.5G |
Frequency Stability (ppm) |
±5 (25℃±5℃) |
Frequency resolution (Hz) |
1 |
Output Power (dBm) |
-55~+10 |
Level Accuracy (dBm) |
±0.65@0 dBm,50MHz absolute |
Level Resolution (dB) |
0.05 |
Level Linearity (dB) |
±0.75 |
Harmonics (dBc) |
<-20 @+5dBm,typical |
Non-Harmonic Spurious (dBc) |
<−30@+5dBm,typical |
External Port |
USB/LAN/RS232/PS2/Parrallel/VGA/GPIB(optional) |
Impedance (Ω) |
50 |
Test Port |
N female 4/2 port |
Format |
Log/Lin/Delay/Smith/SWR/Polar/Real/Imaginary |
Limit Test |
Ripple limit test/Bandwidth limit test |
Maximum Input Level (dBm) |
+10 |
Damage Level (dBm) |
+26(±35VDC, typical) |
System Dynamic Range (dB) |
118(IF bandwidth 10 Hz) |
Directivity (dB) |
46(1MHz~10MHz) |
System impedance (Ω) |
50 |
Test Port |
N female, 2 or 4 ports |
IFBW(Hz) |
10~500K |
Test Speed |
3ms(IFBW:500kHz) |
Scanning Point |
2~20001 |
Power |
AC 150V~230V/50~60Hz, 350VAMax |
Weight (kg) |
20 |
Dimension (mm) |
490×427×234 |